| Sign In | Join Free | My xpandrally.com |
|
Brand Name : KACISE
Model Number : KGD-WQ-510
Certification : CE
Place of Origin : CHINA
MOQ : 1PCS
Payment Terms : L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability : 1000 Piece/Pieces per Week negotiable
Delivery Time : 5-8 work days
Packaging Details : each unit has individual box and all boxes are packed in standard packages or customers requests available
Flow Control Range : 100 - 2000 m³/h
Flow Control Stability : ≤ ±5% of the set value
Flow Measurement Accuracy : ≤ ±1.5% of the reading
Cooling Air Temperature : 23°C ± 2°C
Cooling Air Humidity : 50% ± 5%RH
Cooling Air Filtration Device : Activated carbon filter and H13 - grade particle filter
KGD - WQ - 510 Motor Vehicle Brake Emission Testing System
Product Introduction
The KGD - WQ - 510 Motor Vehicle Brake Emission Testing System is a comprehensive solution specifically designed for the standardized testing of motor vehicle brake particle emissions. It is composed of an air duct control system, a particle sampling system, a particle number analysis system, an inertial brake dynamometer, and a main control system. The main test items include PM2.5, PM10, SPN, and TPN, which can meet the certification test requirements of the Euro 7 emission standard and related research and development test needs..

Product Features
Technical Parameters
| Parameter | Details |
| Flow Control Range | 100 - 2000 m³/h |
| Flow Control Stability | ≤ ±5% of the set value |
| Flow Measurement Accuracy | ≤ ±1.5% of the reading |
| Cooling Air Temperature | 23°C ± 2°C |
| Cooling Air Humidity | 50% ± 5%RH |
| Cooling Air Filtration Device | Activated carbon filter and H13 - grade particle filter |
| Particle Sampling System | |
| Maximum Particle Size Limit | 2.5μm and 10μm |
| Filter Paper Sampling Temperature | ≥ 15°C; No condensation |
| Filter Paper Diameter | 47mm |
| Sampling Flow Rate | 16.7 L/min |
| Sampling Flow Control Accuracy | ≤ ±2% of the set value |
| Particle Number Analysis System | |
| Measurement Principle | Condensation Particle Counting (CPC) |
| Measurement Items | TPM10; SPN10 |
| Maximum Particle Size Limit | 2.5μm |
| Minimum Particle Size Limit | 10 nm (counting efficiency: 65% ± 15%) |
| 15 nm (counting efficiency: >90%) | |
| CPC Measurement Range | 0 - 100000 #/cm³ |
| CPC Measurement Precision | ≤ ±10% |
| Primary Dilution Ratio | 10 |
| Secondary Dilution Ratio | 10-30 |
| VPR Removal Efficiency | >99.9% |
| Response Time | T90 < 5s |
|
|
KGD - WQ - 510 Motor Vehicle Brake Emission Testing System Images |